Prospective style - a bright style that expands horizons, elegant, gorgeous and dazzling
Prospective PL-C
Ceiling: CCS-21
Operation panel: COP-52
Armrest: hairline stainless steel
Floor: stone parquet
Front wall panel: matte stainless steel
Compartment door: matte stainless steel
Wall panel: matte stainless steel

• Style

Transparent on three sides

Hexagon

Semicircle

 

Transparent back side

• Floor parquet reference style (marble or quartz tiles)

CGS51

CGS51

CGS52

CGS52

CGS53

CGS53

 CGS57

CGS57

CGS55

CGS55

CGS56

CGS56

 

 

• Siding color swatches

Mirror stainless steel

Mirror stainless steel

Matte stainless steel

Matte stainless steel

Hairline stainless steel

Hairline stainless steel

Titanium mirror etching

Titanium mirror etching

Titanium-coated stainless steel

Titanium plated stainless steel

 

 

 

• Arrival indicator and boarding indicator

FPI-51

FPI-52

FPI-54

 

• Operation panel

Car operating panel

COP-52 integrated operation panel touch button

 

Car operating panel

COP-62 integrated operation panel touch button

Market operation board

EOP-53 touch button

 

 

 

 

 

 

Market operation board

EOP-63 touch button

 

 

 

 

 

 

• Additional price options

• LED ambient lighting system

The lighting, transition or flashing effects can be changed to match different festivals, situations and decorations, integrating with the design atmosphere of your building, enhancing the texture of the space, and also having energy-saving effects.

 

 

 

• Dedicated LCD monitor

Full-color LCD can be used to display building or home information. Special public places such as restaurants, performance halls, etc. can also be used for commercial displays based on events to provide public information on boarding. Elevator fun.

LCD screen  LCD screen

 

• Access Control System

Chip sensor type: Use the sensor card (buckle) to identify whether your identity is correct to determine whether you can enter the controlled elevator.

Swipe card and password: You can choose to swipe your card or add a password to identify whether the magnetic card or personal password is correct to determine whether you can enter the controlled elevator.

Fingerprint recognition type: The fingerprint recognition system is the most scientific and efficient system, which precisely monitors the identity of persons and can avoid traditional magnetic card damage, password leakage, forgetfulness, loss, etc. question.

Others: Customized access control and pre-hailing services can be provided according to customer needs.

• Light curtain anti-pinch system

The safety touch panel can be set as a light curtain so that passengers can sense it without touching it, providing multiple safety protections.

Light Curtain

 

• Arrest style

SHR-5

SHR-5

WHR-6

WHR-6

 SHR-2

SHR-2

 SHR-3

SHR-3

 

 

 • Standard and optional

Features Category Function name Elegant type Exquisite Prospective
Space and Flexibility Opening method Two central split automatic doors (CO) ●  ●  ● 
Two-piece central side-opening automatic door (2S) ●  - -
Four-piece central split automatic door (4C) - ●  ● 
Indoor operating panel Stainless steel hairline panel ●  - ● 
One-piece door type - ●  ● 
Convenience and thoughtfulness Sill drain hole ●  ●  ● 
Socket for carriage cleaning ▲  ▲  ▲ 
Environment and Safety Current load Prevent overloading device ●  ● 
Pass News Intercoms in carriages and management rooms (boarding areas)
Telephone number (you must bring your own phone number)  ▲  ▲  ▲ 
Anti-pinch Single-sided safety touch panel - -
Double-sided safety touch panels ▲  ●  ▲ 
Ultrasonic door sensor device ▲  ▲  ▲ 
Car door load detection
Door sensor self-diagnosis ▲ 
Infrared light curtain ▲ 
Disaster Protection Seismic operation control device
Power outage lighting device ▲  ▲ 
Automatic power outage arrival device
Water intrusion warning and control
Safe arrival function (default designated floor)  ▲  ▲  ▲ 
Firefighter operating device ▲  ▲  ▲ 
Fire return operation device ▲  ▲  ▲ 
Emergency power operating device ▲  ▲  ▲ 
Guarantee Full Fingerprint recognition control ▲  ▲  ▲ 
Chip sensor control (card, sensor, password)  ▲  ▲  ▲ 
Secured taxi-calling system (exclusive floor)  ▲  ▲  ▲ 
Passcode-based taxi hailing ▲  ▲  ▲ 
Car passenger movement abnormality sensor ▲  ▲  ▲ 
Welfare facilities
(Elegant type only)
Special handrails ▲  ▲  ▲ 
Mirrors and convex lenses ▲  ▲  ▲ 
Braille
Special sub-operation panel ▲  ▲  ▲ 
Wisdom and Technology Ride and hail mode Selective collective ▲  ▲  ▲ 
Uplink or downlink selective collective type
Multiple units linkage control (group control) 
Wrong carriage request canceled
Humanized functions The carriage fun is automatically canceled ▲ 
Automatic passing function when fully loaded ▲  ▲  ▲ 
Automatic adjustment of door opening and closing time ▲  ▲  ▲ 
Closing delay button ▲  ▲  ▲ 
Multi-lingual voice announcement system (welfare facilities)
Dedicated use Control locks on each floor in the carriage ▲  ▲  ▲ 
Specify independent operation when multiple units
Dedicated service operation ▲  ▲  ▲ 
Passenger parking switch
Switch to any non-service building
Self-diagnosis and repair Repeat closing action (removing foreign matter)
Automatically implants after power is turned on
Energy-saving function The cabin fan automatically turns off
Car lighting automatically turns off (subject to type)
Elevator status indication Boarding instructions (exquisite type) ▲  (subject to type)
Dot matrix display in carriages and on board ●  - ▲ 
Monochrome LCD display in carriages and trains - ●  ▲ 
Color LCD display in carriages and buses ▲  ▲  ▲ 
Elevator monitoring Near-end monitoring (management room)  ▲  ▲  ▲ 
Remote monitoring ▲  ▲  ▲ 
Wide-angle CCTV ▲  ▲  ▲ 
      ●Standard equipment ▲Added-on options

 

          Specifications
Passenger elevator model
Passenger load Speed
m/min
Liftway
B1xB2
Car
A1xA2xH1
Open the door
Type
Opening door size
WxH2
Top Distance
OH≥
Machine pit depth
PIT
Reaction force (㎏)
R1 R2
SCP -08 8 people
(550㎏)
60 2250x1650 1400x1030x2300 CO 800x2100 Above 4350 1600 4550 3200
90 Above 4550 1850 6800 5450
SCP -09 9 people
(600㎏)
60 2250x1800 1400x1100x2300 CO 800x2100 Above 4350 1600 5000 4050
90 Above 4550 1850 7500 6050
SCP -10 10 people
(700㎏)
60 2300x1800 1400x1250x2300 CO 800x2100 Above 4350 1600 5330 4200
90 Above 4550 1850 8000 6300
105 Above 4750 2150 12000 9450
120 16000 12550
SCP -11 11 people
(750㎏)
60 2300x1900 1400x1350x2300 CO 800x2100 Above 4350 1600 5650 4450
90 Above 4550 1850 8500 6650
105 900x2100 Above 4750 2150 12700 10000
120 2150 17000 13300
SCP -12 12 people
(800㎏)
60 2300x1950 1400x1400x2300 CO 900x2100 Above 4350 1600 6000 4700
90 Above 4550 1850 9000 7050
105 Above 4900 2150 13450 10550
120 2150 17950 14050
150 Above 5100 2450 21500 16850
SCP -13 13 people
(900㎏)
60 2400x2000 1600x1350x2300 CO 900x2100 Above 4350 1600 6650 5170
90 Above 4500 1850 9950 7750
105 2400x2100 4C 1200x2100 Above 4750 2150 14300 11650
120 19900 15500
150 Above 5100 2450 25000 18600
SCP -15 15 people
(1000㎏)
60 2550x2000 1600x1500x2300 CO 1000x2100 Above 4350 1600 7150 5500
90 Above 4550 1850 10700 8250
105 2550x2000 4C 1200x2100 Above 4750 2150 16050 12350
120 2150 21350 16500
150 Above 5100 2450 25650 19750
SCP -17 17 people
(1150㎏)
60 2600x2100 1600x1600x2500 CO 1000x2100 Above 4550 1600 7770 5900
90 Above 4750 1850 11700 8850
105 2600x2100 4C 1200x2100 Above 4950 2150 17500 13300
120 22350 17700
150 Above 5100 2450 26350 21250
SCP -20 20 people
(1350㎏)
60 2850x2200 1800x1700x2500 CO 1000x2300 Above 4500 1600 8750 6650
90 Above 4750 1850 13150 9850
105 2800x2300 4C 1400x2300 Above 4950 2150 19700 14750
120 26250 19650
150 Above 5100 2450 31500 23600
SCP -24 24 people
(1600㎏)
60 2890x2400 2000x1750x2500 CO 1000x2300 Above 4550 1600 10250 7650
90 Above 4750 1850 15350 11450
105 2850x2500 4C 1400x2300 Above 4950 2150 23000 17150
120 30650 22850
150 Above 5100 2450 36700 27400
Specifications
Passenger elevator model
Passenger load Speed
m/min
Liftway
B1xB2
Car
A1xA2xH1
Open the door
Type
Opening door size
WxH2
Top Distance
OH≥
Machine pit depth
PIT
Reaction force (㎏)
R1 R2
SCB -11 11 people
(750㎏)
60 2200x2800 1300x2300x2300 2S 1100x2100 Above 4350 1600 6800 5600
90 Above 4550 1850 10900 8350
SCB -15 15 people
(1000㎏)
60 2400x3000 1500x2500x2300 2S 1100x2100 Above 4550 1600 8300 6650
90 Above 4750 1850 12400 9950
Machine roomless elevators are used for 12 stops or less than 40M of travel.    The temperature inside the lift should be maintained at 5 Between °C and 40°C, the vertical error of the lift is within 5CM. When adding brakes on the counterweight side, the dimensions of the lift need to be planned separately.

 

 

1400x1350x2300
Specifications
Passenger elevator model
Passenger load Speed
m/min
Liftway
X*Y
Car
A1xA2xHZ
Open the door
Type
Opening door size
WxH2
Top Distance
OH≥
Machine pit depth
PIT
Computer Room Reaction force (㎏)
MAxMBxMH R1 R2 R3 R4
SAP -08 8 people
(550㎏)
60 1800x1630 1400x1030x2300 CO 800x2100 4450 1550 2400x3300x2050 4500 3600 3200 2100
90 1850x1650 4650 1850 3000x3400x2250 6800 5400
SAP -09 9 people
(600㎏)
60 1850x1700 1400x1100x2300 CO 800x2100 4450 1550 2400x3400x2050 4800 3800
3350


2200

90 1850x1750 4650 1850 3000x3600x2250 7200 5700
105 4850 2150 8400 6650
120 13000 10000
SAP -10 10 people
(700㎏)
60 1800x1850 1400x1250x2300 CO 800x2100 4450 1550 2400x3600x2050 5350 4150

3700



2350

90 1850x1900 4650 1850 3000x3600x2250 7950 6250
105 4850 2150 9300 7250
120 13900 10850
SAP -11 11 people
(750㎏)
60 1800x1950 CO 800x2100 4450 1550 2400x3700x2050 5600 4400 4350 2500
90 1950x2000 4650 1850 3000x3700x2250 8400 6600
105 900x2100 9800 7700 5100 3950
120 4850 2150 14800 11500
SAP -12 12 people
(800㎏)
60 1800x2000 1400x1400x2300 CO 800x2100 4450 1500 2200x4000x2050 6000 4600 4400 2650
90 1950x2050 4650 1850 3000x4000x2250 9000 6900

5100


3950

105 900x2100 10500 8500
120 4850 2150 15600 12150
150 5050 2450 21500 16850
SAP -13 13 people
(900㎏)
60 2200x2100 1600x1350x2300 CO 1000x2100 4450 1550 2800x3800x2050 6600 5100 4800 2950
90 4650 1850 3200x3600x2250 9900 7650
105 4C 1200x2100 4850 2150 11550 8900
5850


4550

120 17350 13450
150 5050 2450 24900 18600
SAP -15 15 people
(1000㎏)
60 2200x2250 1600x1500x2500 CO 1000x2300 4450 1550 2800x4000x2050 7100 5500 5200 3200
90 4650 1850 3200x4100x2250 10650 8250
105 4C 1200x2300 4850 2150 12450 9600 6200
4800

120 18650 14300
150 5050 2450 25650 19750
SAP -17 17 people
(1150㎏)
60 2200x2350 1600x1600x2500 CO 1000x2100 4450 1550 3200x4200x2050 7800 5900
7050
4200

90 4650 1850 3200x4200x2250 11700 8850
105 4C 1200x2100 4850 2150 13650 10350
7450


4400

120 20400 15400
150 5050 2450 26350 21250
SAP -20 20 people
(1350㎏)
60 2300x2450 1800x1700x2500 CO 1000x2300 4450 1550 3400x4300x2050 8800 6600 8600 4900
90 4650 1850 3400x4300x2250 13200 9900
105 2500x2500 4C 1400x2300 4850 2150 15400 11550
8900


5050

120 23000 17150
150 5050 2450 31500 23600
SAP -24 24 people
(1600㎏)
60 2500x2500 2000x1750x2500 CO 1000x2300 4450 1550 3600x4400x2050 9950 7300 9100 4500
90 4650 1850 3600x4400x2250 15000 10950
105 2600x2600 4C 1400x2300 4850 2150 17400 12800
9500


5100

120 26000 19100
150 5050 2450 36700 27400
Specifications
Passenger elevator model
Passenger load Speed
m/min
Liftway
B1xB2
Car
A1xA2xH1
Open the door
Type
Opening door size
WxH2
Top Distance
OH≥
Machine pit depth
PIT

Computer RoomMAxMBxMH

Reaction force (kg)
R1 R2 R3 R4
SAB -11 11 people
(750㎏)
60 2200x2800 1300x2300x2300 2S 1100x2100 4000 1600 3200x3400x2050 3900 3050 1200 1800
90 4500 1850 3200x3400x2250 4450 3450
SAB -15 15 people
(1000㎏)
60 2400x3000 1500x2500x2300 2S 1100x2100 4500 1600 3400x4000x2050 4900 3750 1330 2300
90 4700 1850 3400x4000x2250 5600 4300
The machine room type is suitable for elevators with less than 32 stops, the elegant type is suitable for elevators with less than 15 stops, and the exquisite type is suitable for elevators with more than 13 stops.
The temperature inside the lift should be maintained between 5°C and 40°C. Otherwise, air conditioning equipment must be provided, and the vertical error of the lift should be within 5CM.

 

• After-sales service items

1. 24-hour emergency maintenance service.
2. Regular maintenance and inspection.
3. Provide original spare parts and program upgrades.
4. The company provides product liability insurance of NT$64 million. Please note the following when there is an elevator failure or power outage:
    A. Emergency lighting allows passengers to clearly identify buttons and relieve their emotions
    B. The ventilation holes can maintain air circulation in case of failure.
    C. Emergency exit (CNS regulations).
    D. When installing the power outage operation system (optional), you can wait for the system to automatically get out of trouble.
    E. Through the intercom in the carriage, you can communicate with external parties, such as the management room.
    F. Contact our company's service personnel directly.
※ Elevators must not be used during earthquakes, fires, or floods.

Product Q&A

Machine room-less elevator layout diagram

機房式_1.jpg


Machine room elevator layout diagram

無機房_1.jpg