| • Style | |||
|
Transparent on three sides |
Hexagon |
Semicircle |
Transparent back side |
| • Floor parquet reference style (marble or quartz tiles) | |||
|
CGS51 |
CGS52 |
CGS53 |
CGS57 |
|
CGS55 |
CGS56 |
|
|
| • Siding color swatches | |||
|
Mirror stainless steel |
Matte stainless steel |
Hairline stainless steel |
Titanium mirror etching |
|
Titanium plated stainless steel |
|
|
|
|
• Arrival indicator and boarding indicator |
|||
|
FPI-51 |
FPI-52 |
FPI-54 |
|
|
• Operation panel |
|||
|
Car operating panel COP-52 integrated operation panel touch button
|
Car operating panel COP-62 integrated operation panel touch button
|
Market operation board EOP-53 touch button
|
Market operation board EOP-63 touch button
|
| • Additional price options | |||
|
• LED ambient lighting system The lighting, transition or flashing effects can be changed to match different festivals, situations and decorations, integrating with the design atmosphere of your building, enhancing the texture of the space, and also having energy-saving effects.
|
• Dedicated LCD monitor Full-color LCD can be used to display building or home information. Special public places such as restaurants, performance halls, etc. can also be used for commercial displays based on events to provide public information on boarding. Elevator fun.
|
• Access Control System Chip sensor type: Use the sensor card (buckle) to identify whether your identity is correct to determine whether you can enter the controlled elevator. Swipe card and password: You can choose to swipe your card or add a password to identify whether the magnetic card or personal password is correct to determine whether you can enter the controlled elevator. Fingerprint recognition type: The fingerprint recognition system is the most scientific and efficient system, which precisely monitors the identity of persons and can avoid traditional magnetic card damage, password leakage, forgetfulness, loss, etc. question. Others: Customized access control and pre-hailing services can be provided according to customer needs. |
|
|
• Light curtain anti-pinch system The safety touch panel can be set as a light curtain so that passengers can sense it without touching it, providing multiple safety protections.
|
• Arrest style |
||
|
SHR-5 |
WHR-6 |
||
|
SHR-2 |
SHR-3 |
||
• Standard and optional
| Features | Category | Function name | Elegant type | Exquisite | Prospective |
| Space and Flexibility | Opening method | Two central split automatic doors (CO) | ● | ● | ● |
| Two-piece central side-opening automatic door (2S) | ● | - | - | ||
| Four-piece central split automatic door (4C) | - | ● | ● | ||
| Indoor operating panel | Stainless steel hairline panel | ● | - | ● | |
| One-piece door type | - | ● | ● | ||
| Convenience and thoughtfulness | Sill drain hole | ● | ● | ● | |
| Socket for carriage cleaning | ▲ | ▲ | ▲ | ||
| Environment and Safety | Current load | Prevent overloading device | ● | ● | ● |
| Pass News | Intercoms in carriages and management rooms (boarding areas) | ● | ● | ● | |
| Telephone number (you must bring your own phone number) | ▲ | ▲ | ▲ | ||
| Anti-pinch | Single-sided safety touch panel | ● | - | - | |
| Double-sided safety touch panels | ▲ | ● | ▲ | ||
| Ultrasonic door sensor device | ▲ | ▲ | ▲ | ||
| Car door load detection | ● | ● | ● | ||
| Door sensor self-diagnosis | ▲ | ● | ● | ||
| Infrared light curtain | ▲ | ● | ● | ||
| Disaster Protection | Seismic operation control device | ● | ● | ● | |
| Power outage lighting device | ▲ | ▲ | ● | ||
| Automatic power outage arrival device | ● | ● | ● | ||
| Water intrusion warning and control | ● | ● | ● | ||
| Safe arrival function (default designated floor) | ▲ | ▲ | ▲ | ||
| Firefighter operating device | ▲ | ▲ | ▲ | ||
| Fire return operation device | ▲ | ▲ | ▲ | ||
| Emergency power operating device | ▲ | ▲ | ▲ | ||
| Guarantee Full | Fingerprint recognition control | ▲ | ▲ | ▲ | |
| Chip sensor control (card, sensor, password) | ▲ | ▲ | ▲ | ||
| Secured taxi-calling system (exclusive floor) | ▲ | ▲ | ▲ | ||
| Passcode-based taxi hailing | ▲ | ▲ | ▲ | ||
| Car passenger movement abnormality sensor | ▲ | ▲ | ▲ | ||
|
Welfare facilities (Elegant type only) |
Special handrails | ▲ | ▲ | ▲ | |
| Mirrors and convex lenses | ▲ | ▲ | ▲ | ||
| Braille | ● | ● | ● | ||
| Special sub-operation panel | ▲ | ▲ | ▲ | ||
| Wisdom and Technology | Ride and hail mode | Selective collective | ▲ | ▲ | ▲ |
| Uplink or downlink selective collective type | ● | ● | ● | ||
| Multiple units linkage control (group control) | ● | ● | ● | ||
| Wrong carriage request canceled | ● | ● | ● | ||
| Humanized functions | The carriage fun is automatically canceled | ▲ | ● | ● | |
| Automatic passing function when fully loaded | ▲ | ▲ | ▲ | ||
| Automatic adjustment of door opening and closing time | ▲ | ▲ | ▲ | ||
| Closing delay button | ▲ | ▲ | ▲ | ||
| Multi-lingual voice announcement system (welfare facilities) | ● | ● | ● | ||
| Dedicated use | Control locks on each floor in the carriage | ▲ | ▲ | ▲ | |
| Specify independent operation when multiple units | ● | ● | ● | ||
| Dedicated service operation | ▲ | ▲ | ▲ | ||
| Passenger parking switch | ● | ● | ● | ||
| Switch to any non-service building | ● | ● | ● | ||
| Self-diagnosis and repair | Repeat closing action (removing foreign matter) | ● | ● | ● | |
| Automatically implants after power is turned on | ● | ● | ● | ||
| Energy-saving function | The cabin fan automatically turns off | ▲ | ● | ● | |
| Car lighting automatically turns off | ▲ | (subject to type) | ● | ||
| Elevator status indication | Boarding instructions (exquisite type) | ▲ | (subject to type) | ● | |
| Dot matrix display in carriages and on board | ● | - | ▲ | ||
| Monochrome LCD display in carriages and trains | - | ● | ▲ | ||
| Color LCD display in carriages and buses | ▲ | ▲ | ▲ | ||
| Elevator monitoring | Near-end monitoring (management room) | ▲ | ▲ | ▲ | |
| Remote monitoring | ▲ | ▲ | ▲ | ||
| Wide-angle CCTV | ▲ | ▲ | ▲ | ||
| ●Standard equipment ▲Added-on options | |||||
|
Specifications Passenger elevator model |
Passenger load |
Speed m/min |
Liftway B1xB2 |
Car A1xA2xH1 |
Open the door Type |
Opening door size WxH2 |
Top Distance OH≥ |
Machine pit depth PIT |
Reaction force (㎏) | |
| R1 | R2 | |||||||||
| SCP -08 |
8 people (550㎏) |
60 | 2250x1650 | 1400x1030x2300 | CO | 800x2100 | Above 4350 | 1600 | 4550 | 3200 |
| 90 | Above 4550 | 1850 | 6800 | 5450 | ||||||
| SCP -09 |
9 people (600㎏) |
60 | 2250x1800 | 1400x1100x2300 | CO | 800x2100 | Above 4350 | 1600 | 5000 | 4050 |
| 90 | Above 4550 | 1850 | 7500 | 6050 | ||||||
| SCP -10 |
10 people (700㎏) |
60 | 2300x1800 | 1400x1250x2300 | CO | 800x2100 | Above 4350 | 1600 | 5330 | 4200 |
| 90 | Above 4550 | 1850 | 8000 | 6300 | ||||||
| 105 | Above 4750 | 2150 | 12000 | 9450 | ||||||
| 120 | 16000 | 12550 | ||||||||
| SCP -11 |
11 people (750㎏) |
60 | 2300x1900 | 1400x1350x2300 | CO | 800x2100 | Above 4350 | 1600 | 5650 | 4450 |
| 90 | Above 4550 | 1850 | 8500 | 6650 | ||||||
| 105 | 900x2100 | Above 4750 | 2150 | 12700 | 10000 | |||||
| 120 | 2150 | 17000 | 13300 | |||||||
| SCP -12 |
12 people (800㎏) |
60 | 2300x1950 | 1400x1400x2300 | CO | 900x2100 | Above 4350 | 1600 | 6000 | 4700 |
| 90 | Above 4550 | 1850 | 9000 | 7050 | ||||||
| 105 | Above 4900 | 2150 | 13450 | 10550 | ||||||
| 120 | 2150 | 17950 | 14050 | |||||||
| 150 | Above 5100 | 2450 | 21500 | 16850 | ||||||
| SCP -13 |
13 people (900㎏) |
60 | 2400x2000 | 1600x1350x2300 | CO | 900x2100 | Above 4350 | 1600 | 6650 | 5170 |
| 90 | Above 4500 | 1850 | 9950 | 7750 | ||||||
| 105 | 2400x2100 | 4C | 1200x2100 | Above 4750 | 2150 | 14300 | 11650 | |||
| 120 | 19900 | 15500 | ||||||||
| 150 | Above 5100 | 2450 | 25000 | 18600 | ||||||
| SCP -15 |
15 people (1000㎏) |
60 | 2550x2000 | 1600x1500x2300 | CO | 1000x2100 | Above 4350 | 1600 | 7150 | 5500 |
| 90 | Above 4550 | 1850 | 10700 | 8250 | ||||||
| 105 | 2550x2000 | 4C | 1200x2100 | Above 4750 | 2150 | 16050 | 12350 | |||
| 120 | 2150 | 21350 | 16500 | |||||||
| 150 | Above 5100 | 2450 | 25650 | 19750 | ||||||
| SCP -17 |
17 people (1150㎏) |
60 | 2600x2100 | 1600x1600x2500 | CO | 1000x2100 | Above 4550 | 1600 | 7770 | 5900 |
| 90 | Above 4750 | 1850 | 11700 | 8850 | ||||||
| 105 | 2600x2100 | 4C | 1200x2100 | Above 4950 | 2150 | 17500 | 13300 | |||
| 120 | 22350 | 17700 | ||||||||
| 150 | Above 5100 | 2450 | 26350 | 21250 | ||||||
| SCP -20 |
20 people (1350㎏) |
60 | 2850x2200 | 1800x1700x2500 | CO | 1000x2300 | Above 4500 | 1600 | 8750 | 6650 |
| 90 | Above 4750 | 1850 | 13150 | 9850 | ||||||
| 105 | 2800x2300 | 4C | 1400x2300 | Above 4950 | 2150 | 19700 | 14750 | |||
| 120 | 26250 | 19650 | ||||||||
| 150 | Above 5100 | 2450 | 31500 | 23600 | ||||||
| SCP -24 |
24 people (1600㎏) |
60 | 2890x2400 | 2000x1750x2500 | CO | 1000x2300 | Above 4550 | 1600 | 10250 | 7650 |
| 90 | Above 4750 | 1850 | 15350 | 11450 | ||||||
| 105 | 2850x2500 | 4C | 1400x2300 | Above 4950 | 2150 | 23000 | 17150 | |||
| 120 | 30650 | 22850 | ||||||||
| 150 | Above 5100 | 2450 | 36700 | 27400 | ||||||
|
Specifications Passenger elevator model |
Passenger load |
Speed m/min |
Liftway B1xB2 |
Car A1xA2xH1 |
Open the door Type |
Opening door size WxH2 |
Top Distance OH≥ |
Machine pit depth PIT |
Reaction force (㎏) | |
| R1 | R2 | |||||||||
| SCB -11 |
11 people (750㎏) |
60 | 2200x2800 | 1300x2300x2300 | 2S | 1100x2100 | Above 4350 | 1600 | 6800 | 5600 |
| 90 | Above 4550 | 1850 | 10900 | 8350 | ||||||
| SCB -15 |
15 people (1000㎏) |
60 | 2400x3000 | 1500x2500x2300 | 2S | 1100x2100 | Above 4550 | 1600 | 8300 | 6650 |
| 90 | Above 4750 | 1850 | 12400 | 9950 | ||||||
| Machine roomless elevators are used for 12 stops or less than 40M of travel. The temperature inside the lift should be maintained at 5 Between °C and 40°C, the vertical error of the lift is within 5CM. When adding brakes on the counterweight side, the dimensions of the lift need to be planned separately. | ||||||||||
|
Specifications Passenger elevator model |
Passenger load |
Speed m/min |
Liftway X*Y |
Car A1xA2xHZ |
Open the door Type |
Opening door size WxH2 |
Top Distance OH≥ |
Machine pit depth PIT |
Computer Room | Reaction force (㎏) | |||
| MAxMBxMH | R1 | R2 | R3 | R4 | |||||||||
| SAP -08 |
8 people (550㎏) |
60 | 1800x1630 | 1400x1030x2300 | CO | 800x2100 | 4450 | 1550 | 2400x3300x2050 | 4500 | 3600 | 3200 | 2100 |
| 90 | 1850x1650 | 4650 | 1850 | 3000x3400x2250 | 6800 | 5400 | |||||||
| SAP -09 |
9 people (600㎏) |
60 | 1850x1700 | 1400x1100x2300 | CO | 800x2100 | 4450 | 1550 | 2400x3400x2050 | 4800 | 3800 |
3350 |
2200 |
| 90 | 1850x1750 | 4650 | 1850 | 3000x3600x2250 | 7200 | 5700 | |||||||
| 105 | 4850 | 2150 | 8400 | 6650 | |||||||||
| 120 | 13000 | 10000 | |||||||||||
| SAP -10 |
10 people (700㎏) |
60 | 1800x1850 | 1400x1250x2300 | CO | 800x2100 | 4450 | 1550 | 2400x3600x2050 | 5350 | 4150 |
3700 |
2350 |
| 90 | 1850x1900 | 4650 | 1850 | 3000x3600x2250 | 7950 | 6250 | |||||||
| 105 | 4850 | 2150 | 9300 | 7250 | |||||||||
| 120 | 13900 | 10850 | |||||||||||
| SAP -11 |
11 people (750㎏) |
60 | 1800x1950 | CO | 800x2100 | 4450 | 1550 | 2400x3700x2050 | 5600 | 4400 | 4350 | 2500 | |
| 90 | 1950x2000 | 4650 | 1850 | 3000x3700x2250 | 8400 | 6600 | |||||||
| 105 | 900x2100 | 9800 | 7700 | 5100 | 3950 | ||||||||
| 120 | 4850 | 2150 | 14800 | 11500 | |||||||||
| SAP -12 |
12 people (800㎏) |
60 | 1800x2000 | 1400x1400x2300 | CO | 800x2100 | 4450 | 1500 | 2200x4000x2050 | 6000 | 4600 | 4400 | 2650 |
| 90 | 1950x2050 | 4650 | 1850 | 3000x4000x2250 | 9000 | 6900 |
5100 |
3950 |
|||||
| 105 | 900x2100 | 10500 | 8500 | ||||||||||
| 120 | 4850 | 2150 | 15600 | 12150 | |||||||||
| 150 | 5050 | 2450 | 21500 | 16850 | |||||||||
| SAP -13 |
13 people (900㎏) |
60 | 2200x2100 | 1600x1350x2300 | CO | 1000x2100 | 4450 | 1550 | 2800x3800x2050 | 6600 | 5100 | 4800 | 2950 |
| 90 | 4650 | 1850 | 3200x3600x2250 | 9900 | 7650 | ||||||||
| 105 | 4C | 1200x2100 | 4850 | 2150 | 11550 | 8900 |
5850 |
4550 |
|||||
| 120 | 17350 | 13450 | |||||||||||
| 150 | 5050 | 2450 | 24900 | 18600 | |||||||||
| SAP -15 |
15 people (1000㎏) |
60 | 2200x2250 | 1600x1500x2500 | CO | 1000x2300 | 4450 | 1550 | 2800x4000x2050 | 7100 | 5500 | 5200 | 3200 |
| 90 | 4650 | 1850 | 3200x4100x2250 | 10650 | 8250 | ||||||||
| 105 | 4C | 1200x2300 | 4850 | 2150 | 12450 | 9600 | 6200 |
4800 |
|||||
| 120 | 18650 | 14300 | |||||||||||
| 150 | 5050 | 2450 | 25650 | 19750 | |||||||||
| SAP -17 |
17 people (1150㎏) |
60 | 2200x2350 | 1600x1600x2500 | CO | 1000x2100 | 4450 | 1550 | 3200x4200x2050 | 7800 | 5900 |
7050 |
4200 |
| 90 | 4650 | 1850 | 3200x4200x2250 | 11700 | 8850 | ||||||||
| 105 | 4C | 1200x2100 | 4850 | 2150 | 13650 | 10350 |
7450 |
4400 |
|||||
| 120 | 20400 | 15400 | |||||||||||
| 150 | 5050 | 2450 | 26350 | 21250 | |||||||||
| SAP -20 |
20 people (1350㎏) |
60 | 2300x2450 | 1800x1700x2500 | CO | 1000x2300 | 4450 | 1550 | 3400x4300x2050 | 8800 | 6600 | 8600 | 4900 |
| 90 | 4650 | 1850 | 3400x4300x2250 | 13200 | 9900 | ||||||||
| 105 | 2500x2500 | 4C | 1400x2300 | 4850 | 2150 | 15400 | 11550 |
8900 |
5050 |
||||
| 120 | 23000 | 17150 | |||||||||||
| 150 | 5050 | 2450 | 31500 | 23600 | |||||||||
| SAP -24 |
24 people (1600㎏) |
60 | 2500x2500 | 2000x1750x2500 | CO | 1000x2300 | 4450 | 1550 | 3600x4400x2050 | 9950 | 7300 | 9100 | 4500 |
| 90 | 4650 | 1850 | 3600x4400x2250 | 15000 | 10950 | ||||||||
| 105 | 2600x2600 | 4C | 1400x2300 | 4850 | 2150 | 17400 | 12800 |
9500 |
5100 |
||||
| 120 | 26000 | 19100 | |||||||||||
| 150 | 5050 | 2450 | 36700 | 27400 | |||||||||
|
Specifications Passenger elevator model |
Passenger load |
Speed m/min |
Liftway B1xB2 |
Car A1xA2xH1 |
Open the door Type |
Opening door size WxH2 |
Top Distance OH≥ |
Machine pit depth PIT |
Computer RoomMAxMBxMH |
Reaction force (kg) | |||
| R1 | R2 | R3 | R4 | ||||||||||
| SAB -11 |
11 people (750㎏) |
60 | 2200x2800 | 1300x2300x2300 | 2S | 1100x2100 | 4000 | 1600 | 3200x3400x2050 | 3900 | 3050 | 1200 | 1800 |
| 90 | 4500 | 1850 | 3200x3400x2250 | 4450 | 3450 | ||||||||
| SAB -15 |
15 people (1000㎏) |
60 | 2400x3000 | 1500x2500x2300 | 2S | 1100x2100 | 4500 | 1600 | 3400x4000x2050 | 4900 | 3750 | 1330 | 2300 |
| 90 | 4700 | 1850 | 3400x4000x2250 | 5600 | 4300 | ||||||||
| The machine room type is suitable for elevators with less than 32 stops, the elegant type is suitable for elevators with less than 15 stops, and the exquisite type is suitable for elevators with more than 13 stops. | |||||||||||||
| The temperature inside the lift should be maintained between 5°C and 40°C. Otherwise, air conditioning equipment must be provided, and the vertical error of the lift should be within 5CM. | |||||||||||||
• After-sales service items
1. 24-hour emergency maintenance service.
2. Regular maintenance and inspection.
3. Provide original spare parts and program upgrades.
4. The company provides product liability insurance of NT$64 million. Please note the following when there is an elevator failure or power outage:
A. Emergency lighting allows passengers to clearly identify buttons and relieve their emotions
B. The ventilation holes can maintain air circulation in case of failure.
C. Emergency exit (CNS regulations).
D. When installing the power outage operation system (optional), you can wait for the system to automatically get out of trouble.
E. Through the intercom in the carriage, you can communicate with external parties, such as the management room.
F. Contact our company's service personnel directly.
※ Elevators must not be used during earthquakes, fires, or floods.
Machine room-less elevator layout diagram
Machine room elevator layout diagram